Skip Navigation
Skip to contents

KMJ : Kosin Medical Journal

OPEN ACCESS
SEARCH
Search

Search

Page Path
HOME > Search
3 "Soo-Jin Kim"
Filter
Filter
Article category
Keywords
Publication year
Authors
Funded articles
Original article
Troponin I and D-dimer levels as triaging biomarkers to distinguish acute pulmonary thromboembolism from myocardial infarction
Soo-Jin Kim, Moo Hyun Kim, Kwang Min Lee, Jin Woo Lee, Young Shin Cha, Da Eun Koh, Joo Yeong Hwang, Jong Sung Park
Kosin Med J. 2023;38(4):252-258.   Published online December 20, 2023
DOI: https://doi.org/10.7180/kmj.23.133
  • 582 View
  • 15 Download
  • 1 Citations
Abstract PDFPubReader   ePub   
Background
Acute pulmonary thromboembolism (APTE) is often confused with myocardial infarction. Previous studies have shown that patients with APTE exhibit lower initial and peak cardiac troponin I (CTI) levels, but higher D-dimer (DD) levels, than patients with myocardial infarction. The present study aimed to reaffirm the tree model algorithm using an entirely new set of data.
Methods
We reviewed retrospective clinical and laboratory data from patients who were diagnosed with APTE or non-ST-elevation myocardial infarction (NSTEMI) between 2015 and 2016. Subjects who were not classified with a diagnosis or did not have their CTI or DD levels assessed were excluded. We categorized patients according to the previous algorithm and compared the outcomes with the previous test dataset.
Results
The analysis involved data from 156 patients with APTE and 363 patients with NSTEMI. In the validation data set, the APTE group showed higher initial DD levels (9.80±10.84 μg/mL) and lower initial CTI levels (0.17±0.54 μg/mL) than the NSTEMI group. The accuracy rate for the test dataset and the validation set were similar. The test set accuracy rate was 91.0%, while the accuracy rate in the validation set improved to 88.6%.
Conclusions
Patients with APTE exhibited lower initial and peak CTI levels, but higher DD levels than NSTEMI patients. The accuracy rate estimates were similar between the test set obtained from the tree model algorithm and the validation set. The study findings demonstrate that the assessment of cardiac biomarkers can be useful for differentiating between APTE and NSTEMI.

Citations

Citations to this article as recorded by  
  • The old biomarkers you know are still useful: D-dimer and troponin I
    Sanghyun Lee
    Kosin Medical Journal.2023; 38(4): 229.     CrossRef
Case report
Disseminated Staphylococcus aureus infection and acute bacterial pericarditis: a case report
Su Hyun Bae, Song-Hyun Lee, Joon-Young Choi, Bong-Joon Kim, Soo-Jin Kim, Sung-Il Im, Hyun-Su Kim, Jung-Ho Heo
Kosin Med J. 2023;38(2):134-137.   Published online August 16, 2022
DOI: https://doi.org/10.7180/kmj.22.021
  • 1,513 View
  • 36 Download
Abstract PDFPubReader   ePub   
We experienced a case of disseminated Staphylococcus aureus infection with bacterial pericarditis that progressed to septic shock and multiorgan failure despite pericardiocentesis and surgical removal of the original abscess with intensive antibiotic therapy. We report this case because of the patient’s very rare and remarkable echocardiographic findings and highly turbid pericardial effusion.
Original article
Comparison of the radiation dose between dual-acquisition coronary computed tomography angiography and coronary angiography for coronary spasm
Soo-Jin Kim, Moo Hyun Kim, Eun-Ju Kang
Kosin Med J. 2022;37(1):46-51.   Published online March 16, 2022
DOI: https://doi.org/10.7180/kmj.21.035
  • 2,154 View
  • 31 Download
Abstract PDFPubReader   ePub   
Background
Coronary computed tomography angiography (CCTA) is an imaging technique that can be used to evaluate and diagnose coronary artery stenosis. Dual-acquisition CCTA (DA-CCTA) with additional nitrate infusion is a promising alternative noninvasive diagnostic tool, as conventional CCTA has limitations in the diagnosis of variant angina compared to conventional angiographic coronary spasm tests. However, DA-CCTA may pose a potential risk due to radiation exposure. We compared the radiation dose between DA-CCTA and the coronary angiographic spasm provocation test.
Methods
Patients with clinically suspected variant angina at a single hospital between March 2013 and October 2018 were screened and underwent DA-CCTA or a coronary angiographic spasm provocation test. The effective radiation dose required for each approach was compared.
Results
In total, 211 suspected variant angina patients underwent DA-CCTA or the coronary angiographic spasm provocation test. Of these, 49 patients (mean age, 59.8 years; 67.3% men) received DA-CCTA and 162 patients (mean age, 60.5 years; 66.2% men) received a coronary angiographic spasm provocation test. There was a significant difference in the effective radiation dose, with a median dose of 5.1 mSv (interquartile range [IQR], 4.1–9.2 mSv) required for DA-CCTA and a median dose of 10.9 mSv (IQR, 8.4–15.2 mSv) for the coronary angiographic spasm provocation test (p<0.001).
Conclusion
DA-CCTA showed a significantly lower effective radiation dose than the coronary angiographic spasm provocation test required to diagnose variant angina.

KMJ : Kosin Medical Journal